TGA/DTA/ DSC

TGA/DTA/DSC is a thermoanalytical technique which measures heat flow and weight/mass change of a materials as a function of temperature or time in a controlled environment.

The technique can provide information about thermal stability, Oxidative stability and decomposition kinematics of materials. We can identify phase transitions, melting point, enthalpy, composition etc. of a material by utilizing this instrument. The technique have applications in understanding the behavior of a wide variety of materials including polymers, inorganic/organic chemicals, pharmaceutical drugs, composites and many more.

Working Principle

Thermo-Gravimetric Analysis (TGA)– The sample is heated in N2environment at a constant rate and the change in the weight of the substance is recorded as a function of temperature or time.

Differential Thermal Analysis (DTA)- The temperature difference between the sample and the reference is measured at a constant heat flow.

Differential Scanning Calorimetric (DSC)- The difference in heat flow required  between the Sample and the reference to keep the temperature constant, is measured.

Specifications of the instrument

  • Company – TA Instruments
  • Model – SDT 650
  • Temperature Range – Room to 1500°C
  • Linear Heating rate – 0.1 to 100 C/min
  • Sample weight capacity –200 mg
  • Sample Types –Powders, Polymers, Liquids
  • Measurements – TGA/DTA/DSC
  • Environment – N2

  • Internal users & Other Academic Institutes : ₹500/hr
  • Industries/Private laboratories : ₹800/hr

  • Internal users & Other Academic Institutes : ₹500/hr
  • Industries/Private laboratories : ₹800/hr


Download SOP
    • The user must fill the requisition form and provide all the sample details. The form should be duly signed by the authorized signatory of the Institute/ Guide/ HOD and emailed to [email protected]. A confirmation mail will be sent by CIF along with a User Id and final amount to be paid for the facility. After the payment, user can submit the samples in person or post the samples on the following address:
      Central Instrumentation Facility, B409, K. R. Mangalam University Sohna Road, Gurugram, Haryana, India, PIN 122103

For any queries regarding the measurements, please contact, Director, CIF, K.R. Mangalam University, Sohna, Gurugram, Haryana, India 122103 on the email [email protected] within 10 days after receiving the results.

All the communication should be addressed to:

Director

Central Instrumentation Facility (CIF)

Room No: B-409, B-Block, K.R. Mangalam University,

Sohna, Gurugram, Haryana, India

PIN 122103

E-mail:    cif@krmangalam.edu.in