TGA/DTA/ DSC
TGA/DTA/DSC is a thermoanalytical technique which measures heat flow and weight/mass change of a materials as a function of temperature or time in a controlled environment.
The technique can provide information about thermal stability, Oxidative stability and decomposition kinematics of materials. We can identify phase transitions, melting point, enthalpy, composition etc. of a material by utilizing this instrument. The technique have applications in understanding the behavior of a wide variety of materials including polymers, inorganic/organic chemicals, pharmaceutical drugs, composites and many more.
Working Principle
Thermo-Gravimetric Analysis (TGA)– The sample is heated in N2environment at a constant rate and the change in the weight of the substance is recorded as a function of temperature or time.
Differential Thermal Analysis (DTA)- The temperature difference between the sample and the reference is measured at a constant heat flow.
Differential Scanning Calorimetric (DSC)- The difference in heat flow required between the Sample and the reference to keep the temperature constant, is measured.
Specifications of the instrument
- Company – TA Instruments
- Model – SDT 650
- Temperature Range – Room to 1500°C
- Linear Heating rate – 0.1 to 100 C/min
- Sample weight capacity –200 mg
- Sample Types –Powders, Polymers, Liquids
- Measurements – TGA/DTA/DSC
- Environment – N2
- Internal users & Other Academic Institutes : ₹500/hr
- Industries/Private laboratories : ₹800/hr
- Internal users & Other Academic Institutes : ₹500/hr
- Industries/Private laboratories : ₹800/hr
-
- The user must fill the requisition form and provide all the sample details. The form should be duly signed by the authorized signatory of the Institute/ Guide/ HOD and emailed to [email protected]. A confirmation mail will be sent by CIF along with a User Id and final amount to be paid for the facility. After the payment, user can submit the samples in person or post the samples on the following address:
Central Instrumentation Facility, B409, K. R. Mangalam University Sohna Road, Gurugram, Haryana, India, PIN 122103
- The user must fill the requisition form and provide all the sample details. The form should be duly signed by the authorized signatory of the Institute/ Guide/ HOD and emailed to [email protected]. A confirmation mail will be sent by CIF along with a User Id and final amount to be paid for the facility. After the payment, user can submit the samples in person or post the samples on the following address:
How to Book
A confirmation mail of the payment must be sent to [email protected]  with reference code as the subject of the mail.
For any queries regarding the measurements, please contact, Director, CIF, K.R. Mangalam University, Sohna, Gurugram, Haryana, India 122103 on the email [email protected] within 10 days after receiving the results.
All the communication should be addressed to:
Director
Central Instrumentation Facility (CIF)
Room No: B-409, B-Block, K.R. Mangalam University,
Sohna, Gurugram, Haryana, India
PIN 122103
E-mail:Â Â Â cif@krmangalam.edu.in